DIMENSIONS
|
Rating Power |
L |
ΦD |
AL2O3 |
Remarks |
RI |
0.25W |
5.6±0.15 |
2.17±0.05 |
85% |
Φ1752 |
0.25W |
5.9±0.15 |
2.17±0.05 |
Φ1755 |
||
0.5W |
8.5±0.25 |
3.1±0.1 |
Φ2580 |
||
1W |
10.5±0.25 |
3.6±0.1 |
Φ3010 |
||
1W |
11.5±0.25 |
3.6±0.1 |
Φ3011 |
||
1W |
10.5±0.25 |
4.1±0.1 |
Φ3510 |
||
2W |
14.5±0.3 |
4.6±0.15 |
Φ4014 |
||
2W |
14.5±0.3 |
5.1±0.15 |
Φ4514 |
||
3W |
16.5±0.35 |
5.6±0.2 |
Φ5016 |
||
5W |
23.6±0.5 |
7.6±0.25 |
Φ7023 |
RATINGS
Type |
Rtated power(W) |
Resistance Range |
classification |
Max. Working |
Max. Overload |
Remarks |
RI |
0.25W |
5Ω~1M |
5% |
1500V |
2500V |
classification >1% |
0.5W |
2500V |
3500V |
||||
1W |
3500V |
5000V |
||||
2W |
5000V |
7000V |
||||
3W |
10% |
6000V |
8000V |
|||
5W |
10000V |
15000V |
Type |
Rtated power(W) |
Resistance Range |
Resistance tolerance |
Max. Working |
Max. Overload |
Voltage Proof |
RI40
|
0.25W |
1K~1000MΩ |
±1%(F) |
1500V |
2500V |
500 |
0.5W |
2500V |
3500V |
600 |
|||
1W |
3500V |
5000V |
800 |
|||
2W |
5000V |
7000V |
||||
3W |
6000V |
8000V |
||||
5W |
10000V |
15000V |
Remarks :1.Can processing components roda of 1 M to 30 M, more than 1 M classified by 10%.
2. 3 w (Φ5016) not company with specifications, the minimum purchase amount to 10 K.
ELECTRICAL PERFORMANCE
Test Items |
Performance Requirements |
Test Methods |
Resistance |
The resistance value shall correspond with the rated resistance taking into account the specified tolerance |
|
Short Time Overload |
△R≤±(0.5%R+0.05Ω) |
2.5 times rated voltage or Max. overload voltage , whichever is lower, for 5s. |
Rapid change temperature |
△R≤±(0.5%R+0.05Ω) |
-55±3℃、30min; 155±3℃、30min 5 cycles |
Intermittent overload |
△R≤±(5%R+0.1Ω) |
2.5 times of rated voltage for 1S ON,25S OFF;10000 cycles. |
Temperature Coefficient |
TCR≤±150PPM/℃ |
Room Temperature +100℃、and keep on 30~40min |
Endurance |
△R≤±(5%R+0.1Ω) |
70±2℃、1000h,Rated direct voltage 1.5h ON、0.5h OFF cycles. |
Damp Heat Steady State |
△R≤±(5%R+0.1Ω) |
40±2℃、90~95%RH、56 days. |
Anti-surge characteristics |
△R≤±(5%R+0.1Ω) |
Discharge test : According to the following table applied voltage, Charging for 4.5 S and discharge for 0.5 S, for 50 times impact test. |